INSTRUCTION FOR USE - cylinder-regulators.com CHECK IT OUT close
Home » Product Search
MB70

High pressure manifold based on Manyflow unit for middle and low flow rates. It can be used for oxygen and inert gases. It is designed for cylinder or cylinder bundles service. There are non-return valves at the Manyflow inlets, separated isolating valves and one central inlet shut-off valve. UC 500 regulator contains high pressure and low pressure gauges and pressure relief valve. There is outlet low pressure ball valve downstream regulator. Ga

MM400-1

Gas manifold panel with regulators MR60 or MR400 for high-flow applications for different gases with inlet pressure of up to 300 bar. Manifolds contain inlet x-block with non-return valve and filter, purge valve and second inlet from site with the potential to install extension units. Purge valves can be used for pressure release when cylinder/bundle hose is disconnected. There is also a high pressure shut-off valve, regulator with pressure relie

MB400

High pressure manifold based on Manyflow unit for high flow applications. It can be used for oxygen and inert gases. It is designed mainly for cylinder bundles service. There are non-return valves at the Manyflow inlets, separated isolating valves and one central inlet shut-off valve. MR400 regulator contains high pressure and low pressure gauges and pressure relief valve. There is outlet low pressure ball valve downstream regulator. All componen

MAXIFLOW 2/2 Acetylene

Acetylene manifold | two inlets with semi-automatic changeover Part. No. Gas Description Pressure Inlet Outlet F27310035 A with automatic quick-acting shut-off device according to ISO 14114-2018 25/1,5 bar W21,8×1/14“LH male G1/2” male F27310036 A with automatic quick-acting shut-off device according to ISO 14114-2018 and REED contact gauge 25/1,5 bar W21,8×1/14“LH male G1/2&rdquo

MM400-2

Manual changeover manifold with regulators MR60 or MR400 for high-flow applications for different gases with inlet pressure up to 300 bar. Manifolds contain inlet x-block with non-return valve and filter, purge valve and second inlet from site with the potential to install extension units. Purge valves can be used for pressure release when cylinder/ bundle hose is disconnected. There is also a high pressure shut-off valve, regulator with pressure

MS400

The MS400 semi-automatic manifold reduces compressed gases of max. 300 bar to a continuous gas supply of 20 bar or 40 bar. It is designed for two types of gas source (cylinders or cylinder bundles). However, only one side at a time is the operating one and the other is then the reserve side. The MS400 will ensure continuity of gas flow by automatically changing from a nearly empty side to a full (reserve) side. MS400 is a complete valve unit wit

MA70

Automatic change over manifold mounted onto a stainless steel panel and consists of two pressure regulators with inlet and outlet pressure gauge, a switch unit with two magnetic valves including control unit and signal monitoring. Automatic change over for uninterrupted gas flow. Solenoid valves guarantee a maximum of exhaustion of the gas sources (cylinders or bundles). Acoustic and optical gas leakage monitoring via contact pressure gauges and

FILTER F120A

This low pressure acetylene filter is used to avoid of mechanical particles coming from acetylene pipe works. It should be mounted at the outlet point upstream the isolating valve, regulator and flashback arrestor. Art. Nr. Gas Pressure Inlet Outlet 0863529 A Max 1,5 bar G1/2" G3/8" LH

CYLINDER RACKS

Art. Nr. Description 14037116 for 1 cylinder 14037117 for 2 cylinders 14037118 for 3 cylinders

MM70-2 Acetylene

Acetylene manifold | two inlets with manual changeover Part. No. Gas Description Pressure Inlet Outlet F27310034 A with automatic quick-acting shut-off device according to ISO 14114-2018 25/1,5 bar W21,8×1/14“LH male G1/2” male 0768140 A with manual quick-acting shut-off device according to ISO 14114-2014 25/1,5 bar W21,8×1/14“LH male G1/2” male TECHNICAL DATA Body