CV300 BCG CHECK VALVE, FOR PURE GASES 
seat material brass/ceramics, 300 bar working pressure, brass chrome plated

Used in pipelines, the CV300 BCG prevents an undesirable flow in the opposite direction to the main flow direction. 
Mounted in the high-pressure area of manifolds of pure gas supply systems, the CV300 BCG protects the compressed gas cylinders against transfer in the event of incorrect operation. The CV300 BCG can be used in supply systems for inert, flammable and oxidising gases up to a gas quality of 6.0. The use of the check valve is not possible with corrosive gases or their mixtures.

SPECIAL FEATURES

The special seat seal and the use of selected gas-wetted parts allow the use with oxygen up to 300 bar working pressure. The Oxygen ignition test for non-metallic seat sealed check valves which is required during the development phase can be omitted with the CV300 BCG due to targeted material selection.

  • Compact design
  • Designed and approved in accordance with relevant sections of EN ISO 10297:2015
  • Specially cleaned

TECHNICAL DATA

Working temperature: -20°C to +60°C
Inlet connection: NPT 1/4" female
Outlet connection: NPT 1/4" male
Max. working pressure: 300 bar
Length: 54 mm
Weight: 0,07 kg
Material: Brass chrome plated